Common DC Bus Inverter Unit
Vacon NXI00725A5T0CSVA1AF000000

EXW Preț fix plus TVA
5.000 EUR
Stare
Nou
Locație
Töltéstava Ungaria
Common DC Bus Inverter Unit Vacon NXI00725A5T0CSVA1AF000000
Common DC Bus Inverter Unit Vacon NXI00725A5T0CSVA1AF000000
Common DC Bus Inverter Unit Vacon NXI00725A5T0CSVA1AF000000
Common DC Bus Inverter Unit Vacon NXI00725A5T0CSVA1AF000000
more Images
Vacon NXI00725A5T0CSVA1AF000000
Vacon NXI00725A5T0CSVA1AF000000
Vacon NXI00725A5T0CSVA1AF000000
Vacon NXI00725A5T0CSVA1AF000000

Date de bază

Denumirea mașinii:
Common DC Bus Inverter Unit
Producător:
Vacon
Model:
NXI00725A5T0CSVA1AF000000
Stare:
nou

Preț și locație

EXW Preț fix plus TVA
5.000 EUR
Locație:
0184/3. Hrsz, 9086 Töltéstava, Hungary Ungaria
Sunați

Detalii despre ofertă

ID anunț:
A21991108
Actualizare:
ultima dată la 25.05.2026

Descriere

Core Drive Specifications

NXI: NX Inverter Unit. It is designed to be fed by a shared, common DC bus arrangement rather than direct AC mains input.
0072: 72 Amps Nominal Current Rating.Low Overload (Pumps/Fans): Continuous maximum output of 72 A.
High Overload (Heavy Duty): Continuous maximum output of 61 A.
5: Mains Voltage Class. Rated for 380 V to 500 V AC grid systems (which corresponds to a DC bus voltage range of 465 V to 800 V DC).
A: Includes the Standard Alpha-numeric Control Keypad.
Dksdpfx Asy Ud Afsnmjw
5: IP54 (NEMA 12) Enclosure Class. This offers strong, dust-protected, splash-resistant defense for hash operational environments.
T: Standard EMC Emission Level adhering to the IEC61800-3 specification for IT networks.
0: No integrated brake chopper.
C: Physical frame generation / module sizing designated as Frame FR7.
Internal Hardware & Control Boards (SVA1AF00000)

The suffix code segment details the exact internal logic, system software, and factory expansion board routing layout:

S: Air-cooled design system.
V: Internal coating option. It features varnished/coated circuit boards for moisture and corrosive air resilience.
A: Standard Vacon System Interface architecture setup.
1AF00000: This sequence identifies the specific hardware configuration across the control expansion slots (A, B, C, D, and E):A1: OPT-A1 Basic I/O Board installed in Slot A. It provides 6 digital inputs, 1 digital output, 2 analog inputs, 1 analog output, +10V reference voltage, and a +24V auxiliary supply.
AF: OPT-AF Dual Relay Output Board installed in Slot B. It provides 2 programmable changeover relay outputs (NO/NC configuration).
00000: Slots C, D, and E are left empty from the factory, giving you expansion headroom for fieldbus communications (such as Profinet or EtherCAT) if needed
Brand new never used. Please check out our other listings as well.

Furnizor

Înregistrat din: 2020

274 Anunțuri online

Sunați

Trimite solicitare

Terenus 
Germania
Austria
Elveția
Statele Unite ale Americii
Regatul Unit
Franța
Belgia
Spania
Mexic
Italia
Olanda
Polonia
Federația Rusă
Belarus (Republica Belarus)
Ucraina
Estonia
Turcia
Noua Zeelandă
Irlanda
Republica Cehă
Danemarca
Finlanda
Suedia
Norvegia
Luxemburg
Grecia
Lituania
Letonia
Islanda
Portugalia
Brazilia
Venezuela
Argentina
Ungaria
Slovacia
România
Moldova
Slovenia
Serbia
Muntenegru
Albania
Croația
Bulgaria
Macedonia de Nord
Bosnia şi Herţegovina
Israel
Egipt
Maroc
India
Indonezia
Coreea de Sud
Japonia
Thailanda
Malaezia
Vietnam
China, Republica Populară
Taiwan
Iran
Bangladeș
Notă: Cererea dvs. va fi transmisă tuturor vânzătorilor din categoria de utilaje. Prin aceasta puteți primi foarte multe oferte.
Solicitarea nu a putut fi trimisă. Vă rugăm să încercați din nou mai târziu.

Telefon & Fax

+36 62 99... anunțuri