Vötsch climate test chamber VCS³ 7027-10, -72°C to +180°C with humidity control, 270 liters capacityVötsch
VCS³ 7027-10
Vötsch climate test chamber VCS³ 7027-10, -72°C to +180°C with humidity control, 270 liters capacity
Vötsch
VCS³ 7027-10
Stare
Utilizat
Locație
Borken 

Date de bază
- Denumirea mașinii:
- Vötsch climate test chamber VCS³ 7027-10, -72°C to +180°C with humidity control, 270 liters capacity
- Producător:
- Vötsch
- Model:
- VCS³ 7027-10
- Stare:
- folosit
Preț și locație
- Locație:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Sunați
Detalii despre ofertă
- ID anunț:
- A22242832
- Număr de referință:
- 24564
- Actualizare:
- ultima dată la 15.10.2026
Descriere
Vötsch
Type: VCS³ 7027-10
Vötsch climate testing chamber, water-cooled
With a temperature change rate of 10 K/min
Data for temperature testing:
Temperature range: -72°C to +180°C
Temporal temperature deviation in the center of the usable space: ± 0.3 K to ± 0.5 K
Spatial temperature deviation: ± 0.5 K to ± 2.0 K
Temperature change rate
Heating: 10 K/min
Cooling: 14.5 K/min
Data for climate testing:
Temperature range: +10°C to +95°C
(extended climate range: 2°C/95% RH, regulated for a maximum of 2 hours)
Temporal temperature deviation in the center of the usable space: ± 0.2 K to ± 0.3 K
Spatial temperature deviation: ± 0.5 K to ± 1.0 K
Temporal humidity deviation in the center of the usable space: ± 1% to ± 3% RH
Humidity range: 10% to 98% RH
(extended climate range: 2°C/95% RH, regulated for a maximum of 2 hours)
External dimensions: Width 780 x Depth 1895 x Height 1775 (mm)
Test chamber dimensions: Width 580 x Depth 615 x Height 750 (mm)
Test chamber volume: approx. 270 liters
Side opening: 50 mm
Side opening: 125 mm
Data for operation:
LED strip 24 V, 6.8 W / 2 x halogen bulb 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V ± 10%, 50 Hz
Rated power: 14 kW Rated current: 26 A
Fuse, on customer’s side: 63 A, slow-blow
Refrigerant: R404A/R-23
Weight approx. 835 kg
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
Csdpfjzh Huuox Ahhjhd
Anunțul a fost tradus automat. Pot exista erori de traducere.
Type: VCS³ 7027-10
Vötsch climate testing chamber, water-cooled
With a temperature change rate of 10 K/min
Data for temperature testing:
Temperature range: -72°C to +180°C
Temporal temperature deviation in the center of the usable space: ± 0.3 K to ± 0.5 K
Spatial temperature deviation: ± 0.5 K to ± 2.0 K
Temperature change rate
Heating: 10 K/min
Cooling: 14.5 K/min
Data for climate testing:
Temperature range: +10°C to +95°C
(extended climate range: 2°C/95% RH, regulated for a maximum of 2 hours)
Temporal temperature deviation in the center of the usable space: ± 0.2 K to ± 0.3 K
Spatial temperature deviation: ± 0.5 K to ± 1.0 K
Temporal humidity deviation in the center of the usable space: ± 1% to ± 3% RH
Humidity range: 10% to 98% RH
(extended climate range: 2°C/95% RH, regulated for a maximum of 2 hours)
External dimensions: Width 780 x Depth 1895 x Height 1775 (mm)
Test chamber dimensions: Width 580 x Depth 615 x Height 750 (mm)
Test chamber volume: approx. 270 liters
Side opening: 50 mm
Side opening: 125 mm
Data for operation:
LED strip 24 V, 6.8 W / 2 x halogen bulb 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V ± 10%, 50 Hz
Rated power: 14 kW Rated current: 26 A
Fuse, on customer’s side: 63 A, slow-blow
Refrigerant: R404A/R-23
Weight approx. 835 kg
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
Csdpfjzh Huuox Ahhjhd
Anunțul a fost tradus automat. Pot exista erori de traducere.
Trimite solicitare
Telefon & Fax
+49 2861 ... anunțuri
Aceste anunțuri v-ar putea interesa și pe dumneavoastră.
Reușit
Mesajul dvs. a fost trimis.
Anunț mic
Borken
1.620 km
Vötsch VC³ 4018 Cameră de testare climatică / Cameră de testare la temperatură -40/+180°C 190 litri
VötschVC³ 4018
VötschVC³ 4018
Anunțul dvs. a fost șters cu succes
A apărut o eroare